Part No: AN886Issued year: 2017File size: 1mbFile type: pdf
This application note describes the extraction of 96 licit and illicit drugs of abuse from urine prior to UPLC-MS/MS analysis using EVOLUTE® HYDRO CX 96-well plates.
EVOLUTE® HYDRO CX plates offer an efficient way to perform hydrolysis in the well of the extraction plate. This method provides high analyte recovery, reduced extraction time due to the elimination of a sample transfer step as well as the elimination of the column conditioning and equilibration steps, and a reduced risk for sample carryover or cross-contamination due to the elimination of the sample transfer step.
Part No: AN877Issued year: 2017File size: 2.61mbFile type: pdf
This application note describes the operating conditions for the automated fractionation of Extractable Petroleum hydrocarbons (EPH) into aliphatic and aromatic (PAH) fractions using the ISOLUTE EPH SPE column in conjunction with the Extrahera automation system.
Part No: P136Issued year: 2015File size: 0.6mbFile type: pdf
This poster compares the use of supported liquid extraction (ISOLUTE® SLE+) and a novel protein and phospholipid depletion plate (ISOLUTE® PLD+), for the extraction of 25-hydroxy vitamin D. The manual extraction protocols were transferred to an SPE automation platform (Biotage® Extrahera)and method performance versus manual processing compared.
MSACL EU 2015
Part No: PPS362Issued year: 2014File size: 1.23mbFile type: pdf
This product sheet compares automated sample preparation using the Biotage®Extrahera™ to an equivalent manual method utilizing a vacuum manifold. A selection of beta blocker drugs were extracted from pooled
stripped plasma using a supported liquid extraction procedure.
Part No: PPS366Issued year: 2014File size: 1.76mbFile type: pdf
Automated sample preparation using the Biotage®Extrahera™ was compared to an equivalent manual method utilizing a vacuum manifold. Analytes were extracted from pooled stripped plasma using a supported liquid extraction procedure.
Part No: PPS361Issued year: 2014File size: 1.28mbFile type: pdf
This document compares automated sample preparation using the Biotage®
Extrahera™ to an equivalent manual method utilizing a vacuum manifold. A selection of non-steroidal anti-inflammatory drugs (NSAIDS) were extracted from pooled stripped plasma using a supported liquid extraction procedure.
Part No: P174Issued year: 2017File size: 1.44mbFile type: pdf
This poster discusses the potential for a single extraction protocol
for various drugs of abuse classes in whole blood prior to UPLC-MS/MS analysis.
SOFT 2017, Boca Raton
Part No: P157Issued year: 2017File size: 0.8mbFile type: pdf
This poster demonstrates that a large urine panel, comprised of 43 DOAs, from multiple drug classes, can be simultaneously screened by mixed-mode cation exchange SPE (using EVOLUTE EXPRESS CX 96 well plates) despite their disparate intermolecular traits, by thoughtfully selecting appropriate organic wash and elution conditions that simultaneously enable sample isolation and detection along with minimizing sample matrix effects.
The extraction method is automated using the Biotage® Extrahera™ Automated sample Preparation Platform.
MSACL 2017, Palm Springs
SOFT 2017, Boca Raton
Part No: P126Issued year: 2015File size: 0.48mbFile type: pdf
This poster demonstrates the use of a novel protein and phospholipid depletion plate, for the extraction of 25-hydroxy vitamin D from serum. The extraction protocol was ultimately transferred to an SPE automation platform and method performance versus manual processing was compared.
ASMS 2015